Industrial Filters - Zander - Stainless
Steel Microfilters
|
Click on photo for a larger view |
Housing Features:
-
Code 7 "Click-lock system with double
"O" ring and bayonet for positively
locating the element.
-
The "O" ring eliminates the possibility
of particle or liquid bypass therefore
insuring filtration integrity.
-
Highly-polished housing surfaces without
edges or corners. (RA .8)
-
High-quality 304 (optional 316L)
stainless steel construction means no
fouling or corrosion and long service
life.
-
Plenum chamber design improves drainage
from the filter housing when used to
coalesce liquids.
-
Vents tapped 1/4" FNPT.
-
May be used with depth media Series V,
Z, Y, Z and A. Universally acceptable
for all applications.
-
Maximum operating pressures of 232 psig
(higher operating pressure housings
available upon request).
-
EDPM housing seal. Other elastomers
available.
-
Available as connection type: BSP, NPT,
Sanitary Clamp, Milk Pipe, Welded Edge,
Flange, SMS, Socket Weld.
|
The Elements:
The Microfilters are designed to work
efficiently either on their own or in
several combinations depending on the
application.
Microfilter Series V:
The prefilter range mainly takes out
particles from the compressed air. Thanks to
the use of materials specifically developed
for this duty, the user enjoys a long
service life with constant efficiency. The
efficiency is 99.99% of all particles of 3
micron and larger. Fine Particles smaller
than 3 micron are fine particles such as
dust and particularly oil aerosols which
must be filtered out by a fine filter. This
is where the newly developed high efficiency
depth Microfilter with its various grades
are used.
Microfilter Series Z:
Efficiency 99.99% at 1 micron. Oil retention
down to 0.5ppm at 100 psig and 68ºF.
Microfilter Series Y:
Efficiency
99.99% at 0.01 micron. Oil retention
down to 0.01ppm at 100 psig and 68ºF.
Microfilter Series X:
Efficiency 99.9999% at 0.01 micron. Oil
retention down to 0.01ppm at 100 psig and
68ºF. If an even better quality of
compressed air than the series X filter is
required to remove oil vapors, then an
adsorption type filter is required.
Microfilter Series A:
The Microfilter series A incorporates an
activated carbon bed which adsorbs oil
vapor. It is always preceded by a
Microfilter series X to remove all oil
aerosols. |
|
Filter
Model ** |
FILTER
element
type |
CAPACITY
(scfm
at 100 psig |
CONNECTION*
INCHES |
DIMENSIONS
A B C |
MAX
operating
pressure
(PSI) |
S02** |
**09T |
53 |
1/4" |
8.7 |
4.3 |
2.2 |
232 |
S05** |
**09T |
65 |
3/8" |
8.7 |
4.3 |
2.2 |
232 |
S07** |
**09T |
88 |
1/2" |
8.7 |
4.3 |
2.2 |
232 |
S09** |
**09T |
118 |
3/4" |
8.7 |
4.3 |
2.2 |
232 |
S11** |
**13T |
171 |
1" |
12.3 |
5.3 |
3 |
232 |
S12** |
**13T |
224 |
1 1/4" |
12.3 |
5.3 |
3 |
232 |
S13** |
**13T |
294 |
1 1/2" |
12.3 |
5.3 |
3 |
232 |
S14** |
**14T |
459 |
2" |
19.1 |
6.7 |
3.2 |
232 |
S15** |
**18T |
677 |
2" |
31.2 |
6.7 |
3.2 |
232 |
S18** |
**18T |
853 |
2 1/2" |
31.2 |
7.9 |
4.3 |
232 |
S19** |
**19T |
1148 |
3" |
41.6 |
7.9 |
4.3 |
232 |
|
|
|
*
DIMENSIONS ARE FOR BUTT WELD
CONNECTIONS
**Insert appropriate filter designation
(V, Z, Y, X, or A) in place of " ** " |
|
|
|
|
|
Air Compressor Equipment Inc.
P.O. Box 3961, 1901 Baldree Road, Wilson, NC 27895
Toll Free: 800-682-6528 / Phone: 252-291-7808 / Fax: 252-291-1324
/ Email:
info@aircompeq.com
|